<LongName>
fs_act_current
</LongName>
<Name>
acurrent
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Thermal</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Sets the current in the autofocus actuator when the focus servo is disabled by
the head focus off command. See head focus hold.
</text></DescriptionText>
<DescriptionText><text>
The valid range is from -1000 to +1000 mA.
</text></DescriptionText>
<DescriptionText><text>
The relationship between physical lens position and current setting varies from
head to head and over time. Using the acurrent parameter to move the lens does
not position the lens accurately.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>-32767 to 32767</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/focus_off.xml</LinkAddress><LinkTitle>Command: focus off</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:03 2008 PST
</Updated>
<Links>
</Links>
</Parameter>